UK Sales: 0191 418 1122         International: +44 191 418 1133

Menu

www.canford.co.uk

22 December 2024

NTI M4261 MEASUREMENT MICROPHONE For XL2 Analyser, Class 2, without calibration certificate

Stock code
25-624
Brand
NTI (NTI Audio)
Model number
  • M4261
  • 600 040 025
NTI M4261 MEASUREMENT MICROPHONE For XL2 Analyser, Class 2, without calibration certificate
NTI M4261 MEASUREMENT MICROPHONE For XL2 Analyser, Class 2, without calibration certificate

NTI AUDIO XL2 ACOUSTIC AND AUDIO ANALYSER

NTi XL2 is a powerful, portable audio analyser, which, when coupled with a suitable microphone, becomes a sound level meter to Class 1 or Class 2 standard and a comprehensive acoustic analyser as well. Supplied with software which connects the instrument to a PC to transfer data or log data it is an all-in-one tool intended for applications such as live sound, sound installations, recording studios, broadcast environmental noise measurements service and repair centres. The analyser is available as a stand-alone test instrument, with a choice of NTI Audio microphones or in kits together with a microphone, signal generator and other accessories. Firmware packages are offered to add reliable measurement of STI, speech transmission index and extended features for sound level and acoustic measurements.

XL2 Analyser

The hand-held instrument has an LCD showing menu options and measured values. It can be used with the rechargeable Lithium-polymer battery supplied for up to four hours. Dry cell batteries will give a similar life, or a external power supply can be used, which will charge the Lithium polymer whilst in operation. An XLR connector on the top offers a high-impedance, balanced connection for the audio input, with 48V phantom powering available for a microphone. Detection of NTI Audio M4261 or M2211 microphones is automatic. An RCA (phono) socket takes unbalanced signals. A 3.5mm headphone socket provides for monitoring the incoming signal. A microphone is built-in, which may be used for polarity and delay measurements as well as voice note recording to a Mini SD card, not supplied, up to 2GB, which can also be used to record screen shots, log measurements and to record WAV files, AD-PCM compressed as standard, but to 24-bit 48kHz quality with the Extended Acoustic Pack option. There is an internal speaker; a USB interface may be used for recharging the internal Li-Po battery as well as transfer of data.

The XL2 has a flexible user interface; the measurement screens may be personalised and ‘only a limited subset of the comprehensive functionalities enabled for simplified operator interfaces. Advanced users may access all menus, settings and store their preferred measurement configurations’. For basic users the XL2 offers ‘audio and acoustic analyser fixed operator interfaces with specific pre-defined settings. The XL2 boots up with exactly the required measurement parameters according the pre-defined instrument configurations. This ensures accurate measurements achieved by advanced and basic users.’

Features

Standards
  • IEC 61672, IEC 60651, IEC 60804, IEC 61260
  • China: GB/T 3785:2010, GB/T 3241, GB 3096-2008, GB 50526, GB-T_4959-1995
  • Germany: DIN 15905-5, DIN 45645-2, optional: DIN 45645-1
  • Japan: JIS C1509-1:2005, JIS C 1513 class 1, JIS C 1514 class 0
  • Switzerland: SLV
  • UK: BS6698, BS5969
  • US: ANSI S1.4:2014, ANSI S1.43, ANSI S1.11:2014
  • SMPTE ST 202:2010, ISO 2969:2015
Sound levels
  • SPL actual, Lmin, Lmax, Lpeak, Leq, gliding Leq
  • Frequency weighting: A, C, Z (=flat) simultaneously
  • Time weighting: Fast, slow and optional impulse simultaneously
  • Correction values k1, k2
  • Indicators show when sound level limits are exceeded
  • Digital I/O interface for the control of external peripherals
Logging and Reporting
  • All levels simultaneously
  • Short-time levels including spectrum for 1 second or longer
  • Wav-file for listening (compressed)

Real Time Analyzer RTA

The RTA perfectly suits tasks such as optimization of sound systems and rooms. The XL2 measures and logs wideband values and the real time spectrum in 1/1 or 1/3 octave-band resolution according to IEC 61260 class 0. The sound level meter results of the wideband and RTA spectrum are simultaneously available. Frequency weighting: A, C, Z (=flat). Time weighting: Fast, slow and optional impulse.

Acoustic Analyzer

FFT Analysis

The real-time FFT is the ideal tool for visualization of comb filters and narrow band effects. It measures the actual level and the averaged level Leq in three ranges over the entire audio band. The optional Extended Acoustic Pack offers an additional high-resolution Zoom-FFT up to 0.4 Hz steps in the frequency range 5 Hz - 20 kHz and adds the linear audio recording (24 Bit, 48 kHz). The Spectral Limits Option extends the FFT Analysis with trace capturing, relative curve display and comprehensive tolerance handling.

Reverberation Time RT60

The XL2 measures the energy decay in the range from 63 Hz to 8 kHz by the Schroeder method in 1/1 octave bands. Automatic triggering and averaging of multiple measurements simplifies the operation and minimizes the measurement time. Use either an impulse source or an interrupted pink noise as the test signal. The optional Extended Acoustic Pack extends the reverberation time measurement to a 1/3 octave resolution.

Polarity

For a stereo sound image, it is important to match the polarities of the left and right speakers. The XL2 measures the polarity of cables, single speakers and speaker cabinets. The detailed result page displays the measured polarity as octave bands from 125 Hz to 8 kHz. This allows in-depth verification of the polarity - frequency relation. The polarity test signal is provided by the NTi Audio Test CD or the Minirator test signal generator.

Delay Time

The delay function supports the accurate setup of delay lines and thus the optimization of the directionality of the signal source. The XL2 measures the delay time between the electrical reference signal and the acoustic signal from the speaker. The required delay settings are displayed automatically, allowing the audio engineer to set the measured delay time directly into the delay device in the rack.

Analog Audio Analyzer

Level RMS / THD+N

The XL2 with balanced XLR and unbalanced RCA inputs offers a comprehensive, high performance audio analyzer. It simultaneously measures balance, level, distortion (THD+N) and frequency. The internal loudspeaker or headphone output offers audible monitoring of either the input signal or just the residual distortion. The optimized low distortion and low noise design enable level measurements down to -112 dBu and residual distortions typically lower than -100 dB, which is unmatched in handheld instruments.

Audio Spectrum

Spectral audio measurements are offered in the units Volt, dBu and dBV within the following measurement functions: Sound Level Meter (1/3 and 1/1 Octave), FFT, 1/12 Octave (optional)

Scope

The scope function visualizes the waveform of the electrical input signal. It triggers to the fundamental frequency and selects the scaling of the X-axis (time) and Y-axis (level) automatically. The fundamental or most dominant frequency is displayed above the scope screen.

Included accessories: Test signal CD, USB cable, Li-Po battery, hand-strap, operating manual.
Optional accessories: As listed below.

Available sets

600 000 340 XL2 with M4261 microphone. Without calibration certificate
600 000 351 XL2 with M2211 microphone. Without calibration certificate
600 000 401 XL2 with M4261 microphone, Minirator MR-Pro, accessories, and case. Without calibration certificate.
600 040 411 XL2 with M2211 microphone, Minirator MR-Pro, accessories, and case. Without calibration certificate.

FIRMWARE OPTIONS


Cinema Assistant

Discontinued

This option allows the user to efficiently calibrate cinema loudspeakers in accordance with SMPTE ST 202:2010 and SMPTE RP 200:2012.


Data Explorer

Discontinued

This option, once installed onto the XL2, allows the user to import logs and measurement data from the XL2 into PC based software.


Extended Acoustic Pack

Discontinued

This pack offers the addition of the following:
Percentiles: 1%, 5%, 10%, 50%, 90%, 95%, 99%. Time weighting: Impulse. Sound pressure level LIeq, sound exposure level LAE. TaktMax and values as specified in DIN 45645-1. Digital I/O interface. Recording of WAV-files at 24-bits, 48 kHz. High-resolution FFT: Up to 0.4Hz resolution in the range of 5Hz-20kHz.


Projector Pro

An option that allows the user to link the XL2 to a monitor screen or tablet via USB and display the XL2 screen contents for easier navigation and referencing.


Room Acoustics

Discontinued

This allows the user to import measurement data into the PC-based Room Acoustics Reporter software for RTA frequency response analysis.


Sound Insulation

Discontinued

This option allows the import of measurement data into the PC-based XL2 Sound Installation Reporter software for more intuitive analysis and reporting.


Spectral Limits

Discontinued

This option extends the XL2 sound and vibration function modes by adding noise curves, trace capturing, relative curve display, and tolerance handling.


Speech Intelligibility STIPA

Discontinued

This adds single value STI and CIS test result according to IEC 60268-16, 2003 release, DIN VDE 0833-4, IEC 60849, DIN VDE 0828-1. Modulation indices and individual band level results with error indicator, post processing with recorded spectra supported. Test signal: NTI Audio STI-PA signal generated by the MR-PRO, or NTI Audio TalkBox.


Vibration Meter

Discontinued

Enables the user to use the XL2 as a ‘professional vibration meter with broadband measurements and spectral analysis in 1/3 or octave resolution’. Vibration meter also comes with an FFT analysis and oscilloscope function as standard.

MEASUREMENT MICROPHONES


M2211, M2230, M4261

NTi plug-on omni-directional, condenser, free-field measurement microphones M4261 or M2211 form together with the XL2 a ‘comprehensive sound level meter and acoustic analyzer’. The microphones are 48V DC phantom powered and include a pre-amplifier. Both combine a high dynamic range and wide frequency-range with low noise. M2230 and M2211 extended performance measurement microphones have detachable half-inch capsule and offers Class 1 frequency response, the M4261 is a Class 2 device with a fixed, quarter-inch capsule. Each microphone is supplied with a protective pouch, windshield and microphone clamp with thread adapter, 5/8th to 3/8th inches.

M2230 consists of MA220 preamplifier and MC230 or MC230A capsule.
M2211 consists of MA220 preamplifier and 7052 capsule.
M4261 consists of M4261 microphone with permanently installed capsule.
M2230 M2211 M4261
Flatness: Class 1 certified Class 1 Class 2 (IEC61672-1)
Frequency range: 5Hz-20kHz 5Hz-20kHz 5Hz-20kHz
Residual noise floor: 16dBA 21dBA 27dBA Typical
Maximum SPL: 137dB SPL 144dB SPL 142dB SPL THD 3%, 1 kHz
Sensitivity: -27.5 +/-2 dB -34 +/-3 dB -36 +/- 3dB dBV/Pa, typical, 1kHz
Temperature coefficient: -0.01 dB/C 0.015 dB/C 0.02 dB/C -10 to +50C
Output Impedance: 100 ohms 100 ohms 100 ohms Balanced

M2010

Discontinued

A very compact and accurate measurement microphone providing Class 1 accuracy. It has a balanced XLR output and requires an external 10V - 48V DC phantom power supply. Supplied with microphone clamp, wind protection, and case.

Microphone type: 0.5-inch omni-directional pressure microphone
Sensitivity: 35 mV/Pa (-29 dBV/Pa), 1kHz, typical
Frequency response: Class 1, temperature -10 to +50 degrees C
Peak acoustic input: 150dB SPL (A-weighted)
Noise: less than 24dB SPL, A weighted

ACCESSORIES

Power Supply

This powers the analyser and charges the internal Li-Po battery in the XL2 in circumstances where USB charging is inappropriate.


Battery Charger - With battery

This charges the Li-Po battery externally from the XL2. It is supplied with a spare Li-Po battery.


Mounting Adapter

This mechanical adapter piece mounts the XL2 on a microphone stand. Adapters for 3/8 inch or 5/8 inch threaded stands are included. NTI Audio code: 600 000 372.


ASD Cable

This is an five metre cable with male and female 3-pole XLR connectors, used when it is desirable to mount the measuring microphone away from the XL2. Up to four ASD cables may be connected in series. The ASD cable is wired with four connections: the XL2 uses the metal body of the XLR input as an extra conductor. As a result the M4261 and M2211 microphones can be identified automatically. If the microphones are connected with a standard microphone cable, parameters must be entered manually.


System Case

Made from re-enforced plastic and filled with foam, 600 000 701 has dedicated cutouts for an XL2 analyser, a Minirator MR-Pro, and a measurement microphone with spaces for batteries cables and adapters.


SPL Stack Light

This is a tubular lamp fitting, intended for such applications as indicating noise levels at live events or clubs or in noisy industrial environments. The light has three lamp sections, coloured green, amber and red, and connects to the XL2 via the Digital I/O Adapter Box. Connection is via a 5-pin XLR on a two metre captive cable. Fixing holes are provided in the base for permanent applications. Dimensions: 232 x 95 x 95mm. NTI Audio code: 600 000 382.


Digital I/O Adapter Box

This is connected to the digital I/O interface of the XL2 to provide a 'Turnkey solution' controlling an external SPL Stack Light. Limit settings may be customised in the XL2. There is a female 5-pole XLR connector for connection to the Stack Light, a male 3-pole mini-XLR connector to link to the XL2 with the supplied cable (2 metres) and an inlet for the supplied 24V power adapter. Dimensions: 170 x 85 x 35mm. NTI Audio code: 600 000 381.

Ordering Note

Unless otherwise stated, all products are exclusive of calibration certificate(s). Calibration certificates can be purchased optionally along with the product. Please ensure you add multiple calibration certificates if the system you are purchasing includes multiple products.

25-618 is the associated NTi Calibration Certificate for XL2, MR-PRO, MR2, ML1, M2211, M2215, M2230, M4261, MINI-SPL, and AUDIO TALKBOX.